{"product_id":"portable-appliance-tester-kyoritsu-kew-6205","title":"Portable Appliance Tester Kyoritsu KEW 6205 Portable Appliance Tester","description":"\u003ch2 data-section-id=\"1ozif4f\" data-start=\"116\" data-end=\"200\"\u003ePortable Appliance Tester Kyoritsu KEW 6205 Portable Appliance Tester Description\u003c\/h2\u003e\n\u003cp data-start=\"202\" data-end=\"575\"\u003eThe \u003cstrong data-start=\"206\" data-end=\"279\"\u003ePortable Appliance Tester Kyoritsu KEW 6205 Portable Appliance Tester\u003c\/strong\u003e is a reliable and efficient device designed for testing the safety of electrical appliances. This Portable Appliance Tester Kyoritsu KEW 6205 Portable Appliance Tester is widely used by electricians, maintenance teams, and safety inspectors to ensure compliance with electrical safety standards.\u003c\/p\u003e\n\u003cp data-start=\"577\" data-end=\"921\"\u003eBuilt with advanced testing capabilities, the \u003cstrong data-start=\"623\" data-end=\"696\"\u003ePortable Appliance Tester Kyoritsu KEW 6205 Portable Appliance Tester\u003c\/strong\u003e performs essential checks such as earth continuity, insulation resistance, and leakage current. It provides accurate and fast results, helping users identify faults and ensure that electrical equipment is safe for operation.\u003c\/p\u003e\n\u003cp data-start=\"923\" data-end=\"1324\"\u003eThe device features a user-friendly interface with a clear digital display, making it easy to operate even for non-technical users. Its compact and portable design allows convenient use in various environments, including offices, factories, and construction sites. The Portable Appliance Tester Kyoritsu KEW 6205 Portable Appliance Tester is also known for its durability and long-lasting performance.\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-start=\"1590\" data-end=\"1820\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"1594\" data-end=\"1667\"\u003ePortable Appliance Tester Kyoritsu KEW 6205 Portable Appliance Tester\u003c\/strong\u003e is an essential tool for maintaining electrical safety, reducing risks, and ensuring compliance in residential, commercial, and industrial applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan data-spm-anchor-id=\"a2700.details.0.i71.69e62b6buojYCJ\"\u003eMains voltage indlcation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"165\"\u003e\n\u003cp align=\"center\"\u003eDisplay range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e30V-270V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e±5V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eProtective conductor resistance test\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"165\"\u003e\n\u003cp align=\"center\"\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e0.00-20.00Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eOpen circuit voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e5V±0.4V DC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eMeasuring current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e200mA DC(nominal value)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e±3%rdg±5dgt\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eInsulation resistance test\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"165\"\u003e\n\u003cp align=\"center\"\u003eRated volatge\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e250V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e500V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003cp\u003e0.00-20.00MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eNo-load voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e250V DC +20%,-0%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e500V DC +20%,-0%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eShort circuit current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003cp\u003e1.5mA DC or less\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003cp\u003e±2%rdg±3dgt\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eLoad current\/Leakage current test\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"165\"\u003e\n\u003cp align=\"center\"\u003eItem\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eLoad current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eLeakage current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eMains voltage range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003cp\u003e100-253V\/50Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eMeasuring range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e0.10-10.00A rms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e0.10-20.00mA rms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e±10%rdg±5dgt\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e±3%rdg±5dgt\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eRCD test\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eRated voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003cp\u003e230V -15% - +10%\/50Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eRated current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003cp\u003e10mA\/30mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"165\"\u003e\n\u003cp align=\"center\"\u003eFunction\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e× 1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e× 5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eTest duration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e0.0ms-500.0ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e0.0ms-40.0ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eOperating time accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\n\u003cp\u003e±2ms(\u0026lt;=40ms),±8ms(\u0026gt;40ms)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable border=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"165\"\u003e\n\u003cp align=\"center\"\u003ePower source\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eLR6(AA)(1.5V) × 6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eApplicable Standards\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003eIEC\/EN61010-1 CAT II 300V, IEC\/EN61010-2-030,\u003cbr\u003eIEC\/EN61010-031, EN61326-2-2, AS\/NZ3760\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"165\"\u003e\n\u003cp align=\"center\"\u003eDimensions \/ Weight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e261(L) × 104(W) × 57(D)mm \/ Approx. 930g(including batteries)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp align=\"center\"\u003eIncluded Accessories\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cp\u003e\u003cspan data-spm-anchor-id=\"a2700.details.0.i72.69e62b6buojYCJ\"\u003e7277(Mains lead),\u003cbr\u003e7129A(Test lead with Alligator clip),\u003cbr\u003e7161A(Flat test prod),\u003cbr\u003e7276(Adaptor for Extension cord),\u003cbr\u003e9193(Carrying case),\u003cbr\u003e8928(Fuse[10A\/250V]),\u003cbr\u003e9121(Shoulder strap),\u003cbr\u003eBuckle, Instruction manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Lucky Engineering","offers":[{"title":"Default Title","offer_id":51049247047969,"sku":"","price":620000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0908\/8316\/2401\/files\/6205-1.jpg?v=1775803744","url":"https:\/\/luckyengineering.site\/products\/portable-appliance-tester-kyoritsu-kew-6205","provider":"Lucky Engineering","version":"1.0","type":"link"}